Mainframe Technical Parameters
S/N |
Name |
Unit |
Parameter |
Remarks |
|
1 |
|
|
|
According to the holding pressure, the timing will change. |
|
|
PET frame GDL carbon paper/CCM proton film size range |
Maximum length |
mm |
100-600 |
Set arbitrarily within the range |
Maximum width |
mm |
50-200 |
Set arbitrarily within the range |
||
Thinnest thickness |
mm |
≤0.02 |
Set arbitrarily within the range |
||
Cutting size |
Maximum product width |
mm |
150*550 |
|
|
Active area cutting accuracy |
mm |
<±0.05 |
|
||
PET border/GDL carbon paper/CCM stacking alignment accuracy |
mm |
±0.05 |
|
||
Effect of cutting |
|
|
No fibrous burrs and burrs |
||
Tension control accuracy |
N |
±2 |
|
||
Yield |
|
≥99% |
Remove bad incoming materials |
||
|
|
Maximum compatible width: |
mm |
300*550 |
|
GDL dispensing: |
|
Online dispensing |
|
||
Dispensing position accuracy |
mm |
≤±0.1 |
|
||
Rubber line width |
mm |
≤1 |
|
||
Rubber line width accuracy |
mm |
≤±0.1 |
|
||
Seven-in-one material sheet alignment: |
mm |
≤±0.1 |
|
||
The cathode and anode GDL are misplaced:; |
mm |
≤±0.1 |
|
||
Squeeze head parallelism |
mm |
≤0.03 |
|
||
Maximum temperature |
℃ |
200 |
|
||
Seven in one cutting |
mm |
±0.03 |
|
||
Cutting accuracy, product length and width dimensional accuracy |
mm |
≤±0.5 |
|
||
Equipped with visual inspection accuracy ± |
mm |
0.1 |
|
||
|
|
Loading and unloading method |
|
|
Automatic loading and unloading |
Visual inspection Dimensions, accuracy |
mm |
≤±0.1 |
|
||
Quality inspection: |
Visual inspection of MEA surface quality, identification of microporous layer defects, creases, fractures and other defects; |
||||
Air tightness detection |
|
|
Flow Detection & Differential Pressure Detection |
||
Traffic resolution |
ml/min |
0.01 |
|
||
Detection Differential Pressure Resolution |
KPa |
1 |
|
||
Detect repeatability |
|
≤±5%; |
|
||
Upper and lower platen parallelism: |
mm |
≤0.03 |
|
||
Online Impedance Detection: Detection Accuracy |
|
≤±1% |
|
||
Yield rate ≥ 99%, |
|
|
Remove bad incoming materials |
||
Working noise |
dB |
≤70 |
|
||
System stability: |
|
The operating system is sensitive and reliable, the actuator moves accurately, and there is no jam |
|||
Equipment appearance: |
|
There should be no rust or bumping marks on the exposed machined surface. The electroplated parts are bright without spots, scratches and other phenomena. The painted surface is smooth and flat; |
|||
Device body color |
|
Meet requirements according to customer needs. |
|||
|
|
Main function |
Collect material information, collect production process parameter records and air tightness test data and complete binding and recording with MEA products to achieve product information traceability |
||
Complete the binding of MEA product barcodes and component materials; |
|||||
Complete the collection and recording of MEA product air tightness test data |
|||||
The display displays the operating status of the equipment, production data statistics, and product material and air tightness detection information; |
|||||
System stability: the operating system is sensitive and reliable, the actuator moves accurately, and there is no jam |
|||||
10 |
Adsorption speed of manipulator |
S |
1-4 |
Set arbitrarily within the range |
|
11 |
There should be no rust or bumping marks on the exposed machined surface. The electroplated parts are bright without spots, scratches, etc., and the painted surface is smooth and flat |
||||
12 |
System stability: the operating system is sensitive and reliable, the actuator moves accurately, and there is no jam; |