Shielding detection cabin

Item No.: 00158
We have over 30 years experiences on study and design the technique of the Shielding detection cabin, optimize the manufacture technology about the production of Shielding detection cabin.
Description Review
Description
1、Geometry feature  
1.1 Inner volume of test chamber 60m³
1.2 Dimensions inside the test chamber 5000*2200*2200mm(Depth*width*height)
1.3 Dimensions of the test chamber Appr 6300*2600*2850mm(Depth*width*height)
1.4 Test chamber refrigeration unit external dimensions Appr 2400*1800*2400mm(Depth*width*height)
1.5 Fresh air system external dimensions Appr3200*2200*2500mm(Depth*width*height)
1.6 Vacuum system Appr1800*2000*2200mm(Depth*width*height)
2、Main performance indicators
2.1 Temperature range -40℃~+90℃
2.2 Pipeline air pressure range Atmospheric pressure ~50kpa (equivalent to about 5000m)
2.3 The height corresponding to the the setting pressure 46.54kpa→6100m
57.30kpa→4550m
69.66kpa→3050m
79.50kpa→2000m
2.4 Humidity range Relative humidity: 20%R.H~95%R.H (No-load at normal pressure) 
2.5 Temperature range for humidity operation 20℃~65℃, 20%R.H~95%R.H (No-load at normal pressure) 
2.6 Degree of temperature fluctuation  ≤±0.5℃(atmospheric pressure, no-load)
2.7 Degree of temperature deviation ≤±2.0℃(atmospheric pressure, no-load)
2.8 Degree of humidity deviation +2%~-3%R.H(humidity>75%R.H)
±5%R.H(humidity<75%R.H)
2.9 Degree of air pressure deviation ≤±2kpa
2.10 Cooling rate ≥1℃/min(+40℃~-40℃)
2.11 Heating rate ≥1℃/min(-40℃~+70℃)
2.12 Load hydrogen fuel cell
weight:≤400kg
power:150kw
Radiator: placed in the cabin
Review
Review

ver_code
1/3
X
Send your message to us
ver_code